E+H Deltabar PMD75 Differential Pressure Transmitter
Supply voltage | 4…20 mA HART 10,5…45V DC (Non Ex): Ex ia: 10,5…30V DC PROFIBUS PA: 9…32 V DC (Non Ex) FOUNDATION Fieldbus: 9…32 V DC (Non Ex) |
Reference Accuracy | Standard: 0.05% Platinum: up to 0.035% |
Long term stability | 0.03 % of URL/ year 0.05 % of URL/ 5 years 0.08 % of URL/ 10 years |
Process temperature | -40°C…85°C (-40°F…185°F) |
Ambient temperature | -50°C…85°C (-58°F…185°F) |
Measuring cell | 10 mbar…250 bar (0.15 psi…3750 psi) |
10 mbar…250 bar (0.15 psi…3750 psi) |
1 mbar (0.015 psi) |
Vacuum resistance | 50 mbar (0.73 psi) |
Max. Turn down | 100:1 |
Max. overpressure limit | On one side: 420 bar (6300psi) |
Process connection | 1/4-18NPT RC1/4″ |
Material process membrane | 316L, AlloyC, Tantal, Gold-Rhodium |
Material gasket | Viton, PTFE, EPDM, NBR |
Fill fluid | Silicone oil Inert oil |
Material housing | 316L, Die-cast aluminum |
Communication | 4…20 mA HART PROFIBUS PA FOUNDATION Fieldbus |